Shop for replacement windows and you’ll soon run into a handful of small numbers: a U-factor, an SHGC, maybe an air leakage figure or a performance grade like R45. Most of them are window energy ratings, and they’re a reliable way to compare one window with another, but only if you know what each one means and which ones matter most for your home.
The “R” number is the odd one out: it isn’t an energy rating at all, and we explain what it does measure further down.
Who rates windows: the NFRC
The National Fenestration Rating Council (NFRC) runs a voluntary program that tests, certifies and labels windows, doors and skylights based on their energy performance. As the Department of Energy’s guide to window ratings puts it, the NFRC label gives you a reliable way to compare products, and you’ll find it on every ENERGY STAR® certified window.
Two details make these ratings more useful than a brochure claim:
- They cover the whole window. A U-factor can refer to the glass alone, but NFRC U-factor ratings include the frame and spacer too.
- They’re specific. Change the glass package and the numbers change, so two windows from the same series can carry different ratings.
How to read the NFRC label, line by line
The label shows three ratings, plus two that manufacturers can choose to include. Here are the scales ENERGY STAR gives for each rating:
| Rating | What it measures | Typical range | Better is |
|---|---|---|---|
| U-factor | How well it insulates | 0.25 to 1.25 | Lower |
| SHGC | Solar heat let in | 0.25 to 0.80 | Lower in Georgia |
| Visible transmittance | Daylight let in | 0.20 to 0.80 | Higher |
| Air leakage (optional) | Air through the joints | In cfm per sq. ft. | Lower |
| Condensation resistance (optional) | Resistance to condensation | 0 to 100 | Higher |
These ranges cover all kinds of windows, old and new. The windows ENERGY STAR certifies for Georgia sit near the bottom of the U-factor range and below the bottom of the SHGC range, as the criteria further down show.
U-factor
U-factor is the rate of non-solar heat flow through the window: in plain terms, how well it insulates. The lower the number, the better. A low U-factor is what keeps heat in on a cold night, and it’s one of the two numbers ENERGY STAR uses to certify a window. A third pane of glass lowers it further, at a cost; our double-pane vs. triple-pane guide weighs whether that’s worth it here.
Solar heat gain coefficient (SHGC)
SHGC is the fraction of the sun’s heat that gets through the window, either directly or absorbed and then released inside. It runs from 0 to 1, and the lower the number, the less solar heat comes in. The Department of Energy explains the trade-off: a high SHGC collects more of the sun’s warmth in winter, while a low SHGC is better at cutting cooling loads in summer. The right number depends on your climate, which way the window faces and how much shade it gets.
Visible transmittance (VT)
VT is the share of visible light that comes through the glass, from 0 to 1. Higher means a brighter room. It’s worth comparing VT alongside SHGC: the Department of Energy describes a light-to-solar gain ratio (VT divided by SHGC), and the higher it is, the more light a window lets in without adding excessive heat. It isn’t always listed, but you can work it out from the label.
Air leakage (AL)
Air leakage measures how much air passes through the joints in the window, in cubic feet per minute per square foot of window. Lower means tighter. ENERGY STAR notes that most industry standards require an AL of no more than 0.3. The Department of Energy adds an important point: air leakage also depends on proper installation, which every rating assumes. Our guide to drafty windows shows where leaks usually start.
Condensation resistance (CR)
Condensation resistance scores how well the window resists water build-up on a scale of 0 to 100. The higher the number, the less condensation the window allows. Like air leakage, it’s optional, so you won’t see it on every label.
Which window energy ratings matter most in North Georgia
ENERGY STAR qualification is based on U-factor and SHGC only. For a home here, we’d rank the numbers like this:
- SHGC. Our cooling season runs from late spring well into fall, and afternoon sun through west- and south-facing windows is a big part of what overheats rooms. A low SHGC is the Department of Energy’s answer for cutting summer cooling loads, and ENERGY STAR caps it at 0.23 in both of Georgia’s zones.
- U-factor. Winters are mild, but we still get freezing nights, and a low U-factor keeps heat in. Georgia’s ENERGY STAR limits on U-factor are looser than those for northern states.
- Air leakage. Drafts are often the first thing people notice about old windows. A tight window, installed and sealed well, lets in less outside air, whether that’s January cold or July humidity.
- Visible transmittance. Once you’ve chosen a low SHGC, compare VT so you don’t give up more daylight than you need to.
Lower heating and cooling bills are the payoff. See how energy-efficient windows can save you money.
ENERGY STAR window requirements by climate zone
ENERGY STAR sets different window requirements for four climate zones. These are the Version 7.0 criteria, in effect since October 23, 2023, as summarized by Cardinal Glass:
| Zone | U-factor | SHGC |
|---|---|---|
| Northern* | 0.22 or lower | 0.17 or higher |
| North-Central | 0.25 or lower | 0.40 or lower |
| South-Central | 0.28 or lower | 0.23 or lower |
| Southern | 0.32 or lower | 0.23 or lower |
*The Northern zone also allows some trade-offs, such as a U-factor of 0.23 or 0.24 with an SHGC of 0.35 or higher.
Georgia counties fall in two of these zones, South-Central and Southern. Rather than guess which one you’re in, use ENERGY STAR’s climate zone lookup to check your county. Either way, the SHGC limit is the same: 0.23 or lower.
What the performance grade (R65, R45, R40) means
You’ll often see a rating like R45 or R65 on a window spec sheet. It isn’t an energy rating. It comes from the North American Fenestration Standard (AAMA/WDMA/CSA 101/I.S.2/A440), which rates, among other things, how well a window stands up to wind and water.
- R is the performance class. It originally stood for Residential, but the current standard no longer ties a class to a type of building.
- The number is the performance grade. According to the Fenestration and Glazing Industry Alliance, it means the window was tested to that design pressure (the wind load it’s built to handle, in pounds per square foot) and met all of the standard’s other requirements.
- The tests include a structural test at 150% of the design pressure and a water penetration test based on 15% of it.
So a higher number means the window passed tougher wind-load and water tests. Among our Vytex windows, Potomac-hp carries R65, Fortis R45 and Georgetown R40.
Comparing window energy ratings on real windows
Here are the published ratings for the three Vytex series we install, from our windows page and window comparison chart:
| Series | U-factor / SHGC | Air infiltration | Performance grade |
|---|---|---|---|
| Potomac-hp | .20 / .18 | .01 | R65 |
| Fortis | .22 / .20 | .06 | R45 |
| Georgetown | .28 / .21 | .08 | R40 |
A few things to notice. Vytex lists the Potomac-hp and Fortis U-factors with each series’ most efficient glass and Georgetown’s with optional double-strength glass, and the SHGC varies with the glass you choose. Ratings also vary with size and style, so ask for the ratings of the exact windows in your quote. Vytex lists air infiltration in cfm per square foot, and all three are well under the 0.3 figure ENERGY STAR cites.
For VinylMax windows, VinylMax says its IntelliGlass® packages can meet ENERGY STAR criteria, with the right package for your location. Ask us for the ratings of whichever glass you’re considering.
Frequently asked questions
What is a good U-factor for windows in Georgia?
To meet ENERGY STAR here, a window needs a U-factor of 0.28 or lower in the South-Central zone or 0.32 or lower in the Southern zone, along with an SHGC of 0.23 or lower. Lower U-factors insulate better: our three Vytex series are rated between .20 and .28, depending on the series and glass. Beyond that, weigh U-factor alongside SHGC, comfort and budget.
What’s the difference between U-factor and SHGC?
U-factor measures non-solar heat flow, the heat that moves through a window because it’s warmer on one side than the other. SHGC measures heat from sunlight coming through the glass. In Georgia, SHGC does most of its work in summer, while U-factor matters most on cold winter nights.
Does ENERGY STAR look at air leakage or condensation?
ENERGY STAR qualification is based on U-factor and SHGC only, though EPA requires the air leakage rating of ENERGY STAR products to be certified. Condensation resistance isn’t part of the criteria, so compare it separately if condensation is a concern in your home.
Where do I find a window’s energy ratings?
Every ENERGY STAR certified window carries an NFRC label, and manufacturers publish window energy ratings for their products. Before you sign, ask for the U-factor, SHGC and air leakage of the exact windows and glass package in your quote, in writing.
Get your free estimate
Want help making sense of the numbers? Crescent Windows and Doors serves homeowners in Johns Creek, Duluth, Alpharetta, Roswell, Milton, Cumming, Suwanee, Buford and Lawrenceville. We’ll measure your windows, compare your options with you and leave a written quote, with no pressure to buy. Call 470-533-0777 or book your free estimate online.